Otherwise, if no channel is left, it stays pink and you see "Device Offline". Dense cables <ERROR>, Import buses "Device missing channel" #928. Tech Support section is for getting help with FTB related problems. To use - place 2 Wireless Connectors and right click both with a Wireless Configuration Kit. CulDoes • 5 yr. The interfaces also transfer channels and the algorithm that determines what channel gets used for what is kinda terrible. Find products of Replacement Parts with high quality at AliExpress. The tunnels are on the same frequency, so the memory card is working fine, but for some reason, they won't link. The ME Controller is a block added by Applied Energistics 2. Channel Management. I have tried without ME conduits but with regular cable to no avail. The wireless connector from AE2 Stuff also has problems with not transferring signal always. I've created a controller structure so that I could do autocrafting but all of a sudden devices are reporting that they are missing channels when they weren't before. every device that is not directly connected to a controller loses its channel for about 10-15 seconds i play on my local server with the latest Direwolf20 Pack (with a few more mods) ae2: appliedenergistics2-rv2-beta-18 yes i have more than enough channels and about a stack of full dense energy cells yes my controller is a valid structure138. It is also known as an etherchannel, trunk, port bundle, or LACP. Business, Economics, and Finance. ae2. jar. Turn the headphones power on. 그래서 우리는 더 많은 채널을 사용하기 위해 우리는 'ME Controller'라는 장치를 사용할 수 있습니다. When you've connected your pylons to your Spatial IO Port, if everything is cabled correctly, after a short calculation period you should see an efficiency number. Development. . If you remove the ear pad and the padding, you will see the membrane. Official AE2 page on P2P tunnels. I'd recommend building a dedicated Big Reactor with a layout similar to this when you can afford it. If a pattern. Unfortunately, it just says device missing channel. 13. The inventory accessed by the Storage Bus is treated as being part of the ME Network, and can be accessed by the network's automated input/output systems,. ago. To expand on this, p2p cables are not part of the system and thus, need their own source of power. Business, Economics, and Finance. newcomer to AE2. The. I'm guessing the purple cable had 7 used before connecting to the assembler. ChunkLoggerOn=チャンクロギングがオンになりました commands. B:Channels=true. The HUD tooltip will indicate if the device is missing a channel. I tried in singleplayer too, same thing happens, but with a different amount of devices. ME Crafting Terminal: The ME Crafting Terminal is the upgraded version of the ME Terminal which has an integrated crafting grid with access to a ME Network's Networked Storage. Ok, so channels are what are used to transfer data in AE2. Hi, so I've been messing around with AE2 autocrafting, I've had this setup working before, but not anymore. The device that is working and the device that isn't are on the same branch of cable. 8 [Details]: I've stored about 900K items in 5 "256k ME Disk Drive (Deep Item Storage Disk)" of AE2 Things. Step 1: Go to the Bose update webpage. AE2 Import Bus not connecting. 10. You can "program" an interface to move 10 Iron plates into another interface to act as storage, then if you have a crating card it will replace any missing plates until it has 10. Forum Threads (11) 1; 2; Next; Topic Latest Post Replies Views; BarXStop Reviews: Most Effective and Safe Training Device on the Market >> by animmale1 Nov 1, 2022. Messages: 269 Likes Received: 51 Local Time: 7:24 AM. You'll end up with a controller conflict, and the whole thing will be inoperable. Refined Storage is basically a copy of AE1. Search bar bug. My issue is this: when I attach a Smart Cable to something down the line, it says. So I was setting up automation for AE2 components when i came across a problem with the channels, on the import buses one always says "Device missing channel" and I have switched cables to dense cables behind and I cannot seem to fix it when i remove an interface behind one of the inscribers the import buses find. Hello all, I've been feeling like I've potentially been missing an encoding setting. Ensure your device is ‘Paired’. Applied Energistics 2's ME Networks require Channels to support devices which use networked storage, or other network services. 2. Enjoy Free Shipping Worldwide! Limited Time Sale Easy Return. ae2. I usually run that cable to a dense cable that goes into a P2P back to the controller, through a regular cable. lang // Blocks tile. Any device that can access or move stored items requires a channel. Each part on the AE2 system has a small internal buffer. 12. I am using minecraft 1. The problem: In one small area, import and export nodes just tell me they have. OR: If your device supports Near Field Communications (NFC): 1. I’m working on a molecular assembler tower with 5 molecular assemblers in a checker pattern and the 4 empty spots being interfaces for patterns. Some parts of it work perfectly with no trouble. ~800 but with 350 devices that needed a channel. When I open the. The ME Interface is also used in conjunction with the. AE2 - P2P Tunnels Tutorial. AE2 version: appliedenergistics2-rv3-beta-6 This is FTB infinity evolved btw. 한 네트워크에 장치를 8개밖에 못 쓴다니, 말도 안되죠. The Subnetwork with the P2P Channels needs it's own controller becauae it uses more than 8 channels, also the P2P tunnel next to the terminal is facing the wrong way. Disable "handsfree telephony". Probably just 8. 2 participants. Yes, I had the same thought re: space, but I have cells that are completely empty and nothing is even going into the interface. Once and a while, when the energy cells are fully charged, my ME Drive looses power for a couple of minutes and everything says Device Missing Channel, but then eventually power is restored. AliExpressCrafting an ME interface in either form by itself produces the other form. I think there's also Light, Item, and Fluid P2Ps but they seem more situational. This alpha version introduces new options to change how AE2 channels behave in your world. 7. #2. A multiblock structure that connects 2 potentially distant network fragments together. [Feedthebeast] AE2 - Device Missing Channel - Doit casser le contrôleur ME et le remplacer pour le réparer. It is the heart of ME Networks and is used to provide more channels to the network. Right-click the speaker icon and click Playback devices. You really want to be methodical in the way you build your network and avoid loops etc. Wiki. There are 25 devices connected to this output dense cable, however the dense cable only shows 20 channels. So consider this my "dumb" question of the day to you. name=セル作業台 tile. Channel Modes. Type. (Goes for Smart cables and Dense cables). Vote. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. d) Follow the On screen instructions. The 1. Done. 1 RV5 Alpha 6 Forge Version: 1. Additional context. Each face can provide up to 32 channels when connected with an ME Dense Covered Cable. It is the new and overhauled version of the original Applied Energistics mod. Something happened to what I call my main network and all cables show 0 channels used even if I add a new device. It was more of a does anyone know if AE2 has. From the AE2 web site: Dense Cable Higher Capacity cable, can carry 32 channels unlike standard cable which can only carry 8, however it doesn't support buses so you must first step down from dense to a smaller cable (such as ME Glass Cable or ME Smart Cable) before using buses or panels. Then hover over it, it should say YOUR name on the top (Bio. Newcomer to AE2 here. This needs to be the top. Compact Machines and AE2 Help. Controller, crafting-terminal, 1-2 drives and some disks. How can I properly disable the channels from AE2 in ATM7 to the Sky. 19 ATMVB) There is a P2P carrying 32 channel at the other end, I used dense cable that carry 32 channel. the problem is that some of my autocrafting station will not go online they just say "Device Missing Channel" i tried replacing the ME-Core and also split the autocrafting in more autocrafting cores witch there own big smart kabel color to the ME-Core. Incorrect crafting job progress bar (not consumed item) bug. Nov 1, 2022 Go To Latest Post. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. If you can see what's wrong please let. Im currently using a 5x5 (25) wall of ME drives connected with dense cables and it says on 2 of the drives that it has a "channel missing" have tried to downsize to a 4x5 (20) and it still has the same message on 2 drives, ive tried using glass cables, smart cables, and now dense smart cables. and maybe powering subnetworks directly. So I was setting up automation for AE2 components when i came across a problem with the channels, on the import buses one always says "Device missing. Real quick question about ae2 Why do I have to break a cable and replace it in order for the message "Device missing channel" to change to "Device online" or I don't and I just need to wait(10-15 secs) for it to update. It'll happily route 13 things through an interface and have 5 missing channels even if it has another longer path through a dense cable. Closed Novasae opened this issue Feb 22, 2015 · 2 comments. garion77 • 4 yr. However, a regular glass cable will only hold 8. 69. For each Child Interface that is not 'up up', follow the steps in the Resolution Guide - EX. But you could also connect to a second me controller for whatever reason you’d need. I tried in singleplayer too, same thing happens, but with a different amount of devices. I see other streamers (Tubbo in specific) getting a good, high…It's better to set it up in a way where all P2P-Tunnels are on a separate subnet. Shop fishing line trimmer with free shipping and free return. * Note Spatial uses a white list compatibilty system, only tile entities marked as "whitelisted" can be moved with this system, other mod authors can opt-into this, AE2 provides support for itself, and Vanilla. Last modified on 06/21/2014 12:27 PM CDT By AlgorithmX2:Applied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). Extra in-game documentation is. 4 Subordination: Respect My AuthoriTAY . AE2 10. Step 3: Run the Bose Updater . PoisonStone • 6 yr. (For instance Import/Export/Storage Buses, ME Drives or Chests, P2P Tunnels, etc. The Export Bus must be configured with items in its GUI to export it; leaving the configuration blank will result in nothing being moved. The broadcasting. Not sure what caused it, but I had a bank of 6 ME Drives not connected to anything being reported as 12 ME Drives using the Network Tool. Upgrades. Angelin01. CryptoQuick note, sticking the Cell into a crafting grid when it has no Items stored as data will also work to extract the component. ie controller > 8 or 32 channel main cable > 8c. I have an issue with my ME Storage system with AE2. So it takes 2 channels, one channel for each end of the P2P tunnel, to transport 32 channels. This can be tricky if you are changing after you have already started the world, I admit. The_Martoni. TY. The ME Fluid Terminal is a machine added by Extra Cells. with 2-3 controllers, you are unlikely to need to worry about channels more. AE2: PROs: more precise control over items, spatial I/O, allows subnetworking, allows piggy-back setups, auto crafting setups perform faster/smarter and are stackable. 그래서 우리는 더 많은 채널을 사용하기 위해 우리는 'ME Controller'라는 장치를 사용할 수 있습니다. (AppliedEnergistics2) Device missing channel even though only 1 out 8 is used I can't seem to add another storage bus whenever I do it displays "Device missing channel" this part of the network as seen in one of the pictures is using 1 out of 8 channels and the whole setup here is using only 10 channels out of 32 as seen in the 3 picture[AE2] Troubles with P2P tunnel missing channels. I believe that all 4 vertical pylons are required. It only requires you to use AE2 items in the recipe for RS items, so it's not unlocked too early if you drop the mod in. The ME Controller is a block added by the Applied Energistics 2 mod. Below you can see the ME Terminal with a blue rectangle on its back connector, because it has an active channel. P2P can only be connected to the me controller face or a cable directly connected to the controller. At this point, I can place the cable back and everything will go online again. The simplest idea is to replace a Dense Cable with a single P2P Tunnel pair. This allows you to use chests, barrels, or other types of item storage in your networks. The next lesson we need to learn about is efficiency. There's a new configuration option in the general section (channels) which controls this option, and a new in-game comman for operators to change the mode and the config from inside the game. Wiring has its own simple concepts that go along with this channel system: 0. See pic number 2 & 3. yeah. Device Missing Channel on Input P2P ME Tunnel Device Missing Channel on Output P2P ME Tunnel. Disable "handsfree telephony". Im trying to automate a lot of my AE2 system, but I'm running into a problem with one of my import buses. It allows for the extraction of stored liquids. ago. Each thing connected to a cable takes a channel. 한 네트워크에 장치를 8개밖에 못 쓴다니, 말도 안되죠. Since they are pretty much superfluous in a channel-free world, they can be safely removed. This component stores ME Encoded Assembler Patterns inside of it, they can either be loaded before completing the ME Molecular Assembler Chamber, or afterwards. • 2 yr. Again. MCDylanf3. Some help. An instant connection between any two points on an ME Network. Reply Mihoshika. 1. r. 이렇게 채널을 잃어버린 장치들은 정상작동하지 않으며, 'Device Missing Channel'이라고 표시됩니다. Storage, 1-32 depending on how much you want to store. Switching AE2 to no channel (in config) will on world load delete your controllers and not allow you to craft them. Cheap Switch Caps, Buy Quality Home Improvement Directly from China Suppliers:Generator unit voltage frequency operation timing 3 in 1 GV13T digital display meter instrument Enjoy Free Shipping Worldwide! Limited Time Sale Easy Return. I had a weird AE2 problem in the older FTB Infinity pack after a pack update. 10-2. ago. Shows load similarly to ME Smart Cable, with each line. Download and run the Bose Updater app on your computer. Probably power or just lag. I’m probably missing something obvious, but. . Thanks, that was exactly the problem. The other day the exporters stopped working and are now saying device missing channel. AE2 and TE trouble with ME interface. 0 for Minecraft 1. CryptoI set up my first ME controller with ME Drive "with 64k storage cell inside" everything seems to have power and I'm using Dense Smart Cables to connect a Crafting terminal to it. ago. Online Shopping at a cheapest price for Automotive, Phones & Accessories, Computers & Electronics, Fashion, Beauty & Health, Home & Garden, Toys & Sports, Weddings & Events and more; just about anything else Enjoy Free Shipping Worldwide! Limited Time. Jun 23, 2019 Go To Latest Post. Input P2P ME Tunnel Online After Breaking Cable. Here is an imgur album I created (contains screenshots):. yea, the energy accepter is mainly needed for early AE2. You attach the input to your controller and then run a long cheap cable out to where you want. AE2 Version: 1. From there, you can have any number of exit points. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. dense cable (of the covered or smart variety) can transmit up to 32 channels on one line. ExtraCells-1. Hello everybody :) I wanted to set up my base in abit more controlled way so i started using colored cables in AE2. [Environment]: Env: Remote Server & Multiplayer OS: Win10 Ver: ATM-1. Connect the headphones to your computer via a microUSB cable, and visit the Bose Updater in a browser. Fluid devices don't. With over 800 million mods downloaded every month and over 11 million active monthly users, we are a growing community of avid gamers, always on the hunt for the next thing in user-generated content. 可以传输8个频道的方块有:. The enabling/disabling channel is completely random, i can be inside my ME, search some some items and "clic" no more answer, all gray, i check and : "missing channel device" however, and as you can see, only 6/8 channel, and anchor cable used for avoid any routing mistake. Check if the energy cells actually drained. 10-rv3-beta-77-GTNH-1-gc1570f3. Items that it will pull out can be whitelisted by adding them via the GUI; otherwise it will attempt to pull out all items from the adjacent inventory. 1492-1. They also have to be branching out of that main cable with a 8 channel cable. To expand again, that single cable is a new network, so it need power and, if more channels are. AE2 P2P Problem (Explanation on Comments). However , when I re-entered the save or waited a long time, the problem was solved. Labels. I would suggest the following. Inscribers can go die in a fire. Just to bring it under some AE2 user's attention again that this is still happening. In the setup with seven machines, using the main network would require 18 channels (7 interfaces, 7 import buses) if you were just to use AE2. It'll happily route 13 things through an interface and have 5 missing channels even if it has another longer path through a dense cable. Fourth - there should be a channel being used on your P2P "service" network for each connected P2P device (assuming none of them are pointing the wrong way) as the P2P service networks rarely include a ME controller this means they max out at 8 P2P tunnel devices - for between 4 and 7 tunnels depending on how they are linked. Please do not misunderstand me closing this issue, but. Glass, Covered and Smart cables all support 8 channels. Been a while since I had to touch AE2. You need to put a bit of quartz fibre on the controller and then attach the glass fibre to that. Also, you have to connect each sixpack to the cable of the previous module with a quartz cable. 1: 945 AE2 stuff crash while launching (stone block) >>Business, Economics, and Finance. 1. The best, most elegant way to automate them is to brute force them with Steve's Factory Manager. Specifically, it can only have 8 devices on the network (8 channels). The way I connect my network is using dense smart cables so I can carry more channels and keep track of. But from what it sounds like, a single sense cable should let it work. I know molecular assembler and pattern provider only carry 8 channel but there is multiple contact point between the molecular assemblers and the dense cable. Off of the dense cable I have 4 ME cables coming off(1 ME. If you input too much power into the network so they fill up near-instantly as you approach, use a TE cell, EIO capacitor or similar device to throttle your input. 0 alpha that provides wireless connections. AE2 Molecular Assemblers not working. I’m probably missing something obvious, but. You can't have more than 1 controller on a network, but adjacent controllers form a multiblock, allowing more sides. The rate of export can be set with different levels of power consumption. Everything else, including most blocks from AE2, transfer only 8 channels. Move channel mode config to a configuration in the serverconfig folder. newcomer to AE2. the problem is that some of my autocrafting station will not go online they just say "Device Missing Channel" i tried replacing the ME-Core and also split the autocrafting in more autocrafting cores witch there own big smart kabel color to the ME-Core. A controller can power 32 devices from one face, but a normal ME cable only has space in it to carry 8. Devices go offline when ME Quantium Link online #1664. Build a Crafting CPU somewhere in the network to manage the crafting. The interfaces also transfer channels and the algorithm that determines what channel gets used for what is kinda terrible. Also, interesting thing to note about most AE2 devices (such as ME drives): they can transfer power and channels to adjacent AE2 devices without needing cables for that, so all but about 3 of the cables you put in the back are redundant. My storage drives are on a subnetwork (so storage bus on the main, pointing into ME interface on the sub), but I replicated that in my creative setup just to make sure that wasn't the. CryptoDoesn't have to be about your main project - though sometimes a little world building the main plot will never touch on can be fun. Real quick question about ae2 Why do I have to break a cable and replace it in order for the message "Device missing channel" to change to "Device online" or I don't and I just need to wait(10-15 secs) for it to update. Each Spatial Pylon Multiblock requires a channel ( 1 per strand of blocks, not 1 per Spatial Pylon ) to function. (dense) energy cells, they seem to be missing in your pictures. 10-10. My ME interfaces say "device missing channel" when I am only using 23/32 channels. does ANYONE know why there is no ME. P2P stands for Point to Point. The text was updated successfully, but these errors were encountered:The ME Storage Bus, when attached to another inventory block in the world lets you access that inventory via networked functions. AE2 doesn't take power direct to the controller. Then you run a separate cable (use a special color for. Leave the Grey row blank to pass-through duds, with Unmapped = Yes. So it takes 3 channels to split 32 channels between 2 destinations. Even though it might look complicated at first it really isn't, like at all, and is such a cool mechanic to play. Some Dense cables should fix this. You can always use the storage bus -> interface technique to connect additional storage networks. This can be done via the ME Interface Terminal, or you can just place it there by hand. Cheap Tool Parts, Buy Quality Tools Directly from China Suppliers:010220 D knife set AEZ narrow for domestic and imported runners series ultra Pro (HM/ST) dl. I had the same problem (although on the right ear). The best and most efficient way to take advantage of p2p's is actually to have 2 seperately controllers, 1 that is a large controller that has. As all cables except dense cables only can. by pyroblaze202. Here you see the devices you have available to record sound. B:PowerGen=. jar. yeah. AE2より新しく追加された概念。. It's on Also my ds18b20 is getting no…So I was setting up automation for AE2 components when i came across a problem with the channels, on the import buses one always says "Device missing channel" and I have switched cables to dense cables behind and I cannot seem to fix it when i remove an interface behind one of the inscribers the import buses find their channels, looking at the. Some help. Once a controller is in place, that's the best way to power your network. Other factors such as poor I/O response time, high paging rates. No branches or pull requests. Each subnetwork of 6 drives, ME Interface and ME Storage bus form an ad-hoc network without a controller. The ME Dense Cable is the only cable that can support 32 channel simultaneously so it can be used as a main data line to connect to another ME Controller or branch off into 8 channel distribution lines via ME Glass Cable, ME. ago. Most devices on a network require a channel to operate. I am not sure my controller setup is right. The P2P Tunnel cannot extract items from machines, a pipe transport system or ME Export Bus is used or items can be manually. You could easily have 9 things on a non-dense cable line, or have a long string of blocks eating channels out of an adjacent dense cable. WAILA does not report "Booting" as state for any of the interfaces that are stuck. At my Thaumcraft Base I have a quantum link with a blue dense cable coming out the top. Murphy will pick the 2nd. Any suggestions?Business, Economics, and Finance. Bose SoundLink Flex Bluetooth Speaker . CryptoAfter restarting Mobile device, try connecting Bose connect to Soundlink Mini II and then check if the issue still occurs. Nothing I've tried fixes the issue. You can put 6 of them around the pattern provider, assuming you don't go over channel limit. I am not experienced with the United Airlines App, but this fix works for Windows interactions! On my end, There is a driver for "Bose AE2 Soundlink Hands-Free. Follow these steps: a) Press the ‘ Windows + W ’ key on the keyboard. I'd simply set the device based entry to 1 and see what happens. 7 Are there max channel per a controller? I have enough power but some random ae elements missing channel. . Each device takes one channel. Unless you disable channels in the config file. Rest of the video is a more in-depth demonstration of how they work, and how to design with them in mind. Ah, read through some more threads after messing with it on my own and was directed to the AE2 wiki, and it does indeed look like you cannot nest P2P Tunnels: "However with the great flex-ability they give you comes a limitation, the channel of a p2p tunnel cannot be carried by another p2p tunnel, meaning that you cannot nest them. . 58. The ME Import Bus requires a channel to function. For a Bluetooth headphone, the SoundLink Around-Ear Wireless Headphone II version provides excellent sound, is comfortable to wear even for long hours, and delivers good battery life of around 15. It imports items from an attached inventory into the ME Network. Other information like is a device connected or not is shown in the WAILA tooltip. When I put a ME Interface on the second enhanced alloy smelter and a regular alloy smelter the first ME Interface on the first alloy smelter goes offline and in tooltips saying "Device missing channel" but it has 6 channels available. The ME Fluid Export bus has many potential uses. p5k likes this. It is the heart of ME Networks and is used to provide more channels to the network. CryptoOne of those fluix cables only supports 8 channels, so if you add a 9th it will say that message. Note that this solution addresses just one possible source of a missing channel end or device end on a paging volume. I have 3 main Smart Cables going into a Dense Energy Cell, and the three have channel values as follows: Bottom Right =4, Top left =5, and the bottom left =1. Also see Spatial IO Compat Project. Then place your power generator adjacent to that. i hope you are aware that EVERY device from AE except for the controller behaves like a standard ME cable and reroutes up to 8 channel to devices facing each other. That multiblock just needs 1 channel and it will connect fine to any AE2 cable. 3. ago. Also, a Network Visualization Tool will help diagnose similar issues, and let you see Channel routing visually all over your network, it's a. Input P2P ME Tunnel Online After Breaking Cable. I want to use green cable for my storage/crafting grid and all my crafting cpu`S connect without issue. The ME Glass Cable is a block added by Applied Energistics 2. It is the new and overhauled version of the original Applied Energistics mod. There's a new configuration option in the general section (channels) which controls this option, and a new in-game command for operators to change the mode and the config from inside the game. This alpha version introduces new options to change how AE2 channels behave in your world. This may be a tad late but it's not only a power issue. On this particular map, only one meteor was found and we pregenerated a 3km radius map. jar. Im currently using a 5x5 (25) wall of ME drives connected with dense cables and it says on 2 of the drives that it has a "channel missing" have tried to downsize to a 4x5 (20) and it still has the same message on 2 drives, ive tried using glass cables, smart cables, and now dense smart cables. Again any help is just great! run: Minecraft Version: 1. Created by crafting 8 ME Quantum Ring and a ME Quantum Link Chamber and placing the ME Quantum Link Chamber in the center, and sourrounding it in the 8 ME Quantum Ring. Jul 16, 2019 Go To Latest Post. r/feedthebeast. This means you can output to as many points as you want, but only input at a single point per tunnel. For the processors, you can either pump in redstone/silicon and have the pattern just say circuit -> processor, or you have have the pattern say circuit+redstone+silicon->processor, have the interface push into a chest, and then filter items to different sides of the inscribwr. 2. I am not experienced with the United Airlines App, but this fix works for Windows interactions! On my end, There is a driver for "Bose AE2 Soundlink Hands-Free. An updated follow-up video about dedicated P2P tunnel networks. 그래서 우리는 더 많은 채널을 사용하기 위해 우리는 'ME Controller'라는 장치를 사용할 수 있습니다. This type of network is also called an Ad-hoc network (basically a bunch of devices connected to each other without some kind of controller managing data I/O). AE2 Version: 1. Other Interfaces are offline because they are missing channels. ~800 but with 350 devices that needed a channel. Also, double check your channels, if there are two equal length routes between a device and the controller, the. Each face can provide up to 32 channels when connected with an ME Dense Covered Cable. AE2 Device Missing Channel. You might poke around using this device on your networks and verify that the system returns the devices that are physically there. One of the many reasons I don't like ae2 very much, but this pack doesn't have refined so I'm stuck with it. An import bus takes a channel, a disk drive takes a channel, a terminal takes a channel, every machine takes up just one channel. Some help. – SevenSidedDie. . I am able to reliably repeat this issue on my. Update the headphones using your computer to the latest firmware manually. However, trying to link a tunnel causes the one downstairs to say device missing channel for a split second, while saying unlinked, then updates to say device online, but it still says unlink. I craft 2 fluid drives and put them in the drive bays, I then make a fluid import bus and connect it to a tank. I'm still fairly new to AE, and I'm aware of smart cables and smart dense cables which are extremely helpful, though quite expensive at this point. AE2 Device Missing Channel >> by ItsMeCryptic Jul 16, 2019. 1. on the plus side, 1 controller gives 32 channels per side, or 192 channels (1 is removed as you need an energy acceptor at least). Cheap Pillow Case, Buy Quality Home & Garden Directly from China Suppliers:The Legendary Studio Pillow Case Printed Home Soft Throw Pillow Sun Studio Music Musician Song Songwriter Singer Duo Enjoy Free Shipping Worldwide! Limited. Cryptoyou dont. Once this is done, restart the computer and check the status. For a start, a simple 1k Crafting Storage should be enough. And that ae2 will take the shortest path to the controller for stuff that needs channels, even if that path is through an interface that can only transmit 8 channels (7 + the interface) through it. Any data-storing or data-using device needs a channel. AyeItsKatieMC Well-Known Member. You need to put a bit of quartz fibre on the controller and then attach the glass fibre to that. It exports items from an ME Network to the attached inventory.